Celestron S-55F Bedienerhandbuch

Stöbern Sie online oder laden Sie Bedienerhandbuch nach Teleskope Celestron S-55F herunter. Celestron S-55F Instruction manual [en] Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 45
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 0
1
For your convenience: the HELP button brings up this Instruction Manual. You can:
Put cursor on page number in Table of Contents; click to go to topic (cool!)
Use View/Zoom and arrow buttons to examine details of drawings
Use Edit/Find for word search
Print whole or part of manual if desired
Download the newest RFCP and manual from our website
MUST HAVE MS WORD INSTALLED ON YOUR COMPUTER
TECHNICAL INNOVATIONS, INC.
7851 Cessna Ave.
Gaithersburg, MD 20879
301-977-9000
301-977-1106 (FAX)
RoboFocus
(Temperature Compensated)
Version 3.X Firmware
Version 3.2.X Software
Jan. 6, 2003
Notice: This instruction manual may be used for all versions of RoboFocus. However,
versions of the RoboFocus Control Program (RFCP) dated prior to Nov 2001 will not
show the full range of capabilities of the system. We recommend that you download the
latest RFCP from our website (free) at
www.homedome.com/Downloads
. See Ch. 1.
CAUTION
Technical Innovations, Inc. is not responsible and assumes no liability for any damage or injury
arising from assembly or use of this product. While the instructions include cautions and warnings, it is
ultimately the customer who must exercise good judgment and care during assembly and operation to avoid
damage to materials or persons, and it is the customer who assumes all risk and liability. Under no
circumstances will Technical Innovations, Inc. be responsible for consequential damages to person or
property.
All portions of this instruction manual are copyrighted by Technical Innovations, Inc. 2002 and
are protected under the laws of the United States. This document may not be reproduced without the consent
of Technical Innovations, Inc. except for use by the purchaser.
Seitenansicht 0
1 2 3 4 5 6 ... 44 45

Inhaltsverzeichnis

Seite 1 - RoboFocus

1 For your convenience: the HELP button brings up this Instruction Manual. You can: • Put cursor on page number in Table of Contents; click to go t

Seite 2 - Table of Contents

10 RoboFocus Electrical The RoboFocus control box has five electrical connections. First, on the left end of the box: • “+12V” — 12VDC (positive)

Seite 3 - 1. Introduction

11 scope at a star, then close the port (while leaving the program running). Switch to the focuser control program, open the COM connection, thus c

Seite 4

12 3. Operation of RoboFocus Introduction The operation of the RoboFocus begins with a brief initial check in which you will assure that the direc

Seite 5 - 2. RoboFocus Installation

13 • If you want to retrain, you can do so at any time. However, the usual problem is that you removed or turned off the RoboFocus and then manuall

Seite 6

14 and calibration are selected in the temperature compensation screen. Note that Celsius and Fahrenheit cannot be selected until temperature calibra

Seite 7

15 IN/OUT. On the left is a box into which you can type your intended relative motion, e.g., 50 steps. Now you can click IN or OUT and the focuser

Seite 8

16 Get/Set Position. If you enter a Zero in the field (or hit refresh), RoboFocus will respond with the current position. You can always send a pos

Seite 9

17 longer travel without resetting the position count. If you find that you need a finer focus adjustment, simply decrease the number of microsteps

Seite 10

18 • Remote Power channels on/off • Duty cycle of stepping motor when at rest (power consumption) • Step Rate of motor when running (motor speed),

Seite 11

19 To operate the remote power module remotely, simply click on the appropriate button in the RFCP. The color will show that the channel is on. W

Seite 12 - 3. Operation of RoboFocus

2 Table of Contents RoboFocus™...

Seite 13

20 Trouble Shooting Guide Problem Cause Cure RFCP will not connect to controller Error in Connections Use of Improper or faulty connecting cables

Seite 14

21 4. Temperature Compensation Introduction This button on the main control screen brings up the temperature compensation function of RoboFocus.

Seite 15

22 Note: temperature is measured using the built in temperature sensor in the RoboFocus controller. The temperature readings are in raw temperature c

Seite 16

23 • You may reorganize the data by date/time, temperature, or position by clicking on the column headings or select an option from the “sort order”

Seite 17

24 • Select when/how often the temperature compensation is to be done. You can operate manually anytime by pressing the MANUAL button whenever you

Seite 18

25 • The internal temperature of the controller is increased if the duty cycle is set above zero or if the controller is placed with the sensor towa

Seite 19

26 5. Focusing Strategies Introduction There are as many focusing strategies (almost) as there are astronomers. Regardless of the method you use,

Seite 20

27 the focus out 0.001 inch. Remember that a move of 5 steps (using the RFCP) at a step size setting of 4 corresponds to a move of 20 microsteps. T

Seite 21 - 4. Temperature Compensation

28 Before you can effectively autofocus, you must have set up the RoboFocus properly. These are some good starting points to use. The user will usua

Seite 22

29 RFCP will be faster! When you are near best focus, adjust the exposure and star choice to get about 10,000 counts. Write down the focuser positi

Seite 23

3 1. Introduction Introduction The RoboFocus is a remote focus driver to be installed on your existing focus mechanism. RoboFocus provides digita

Seite 24

30 do the initial training, and then follow the instructions. Note that FocusMax allows you to choose your star and to control many other properties

Seite 25

31 ASCOM and Scripting The RoboFocus control program is available with full ASCOM scripting interface. We are unable to provide training or exampl

Seite 26 - 5. Focusing Strategies

32 Appendix 1 Software Commands Although not discussed above, the processor includes coding to allow one or both ends of the focuser travel to i

Seite 27

33 FO?XXXXXZ. Commands RoboFocus to move outward by ?XXXXX steps then sends current position. Note actual limit is 65K (one digit is spare). FS?XX

Seite 28

34 Appendix 2 Schematic Diagram RoboFocus Stepper Colors DB9 HURST(standard) NIPPON PF 1 coil A BLK YEL 2 coil A WHI ORG 3 coil B

Seite 29

35 Appendix 3 Serial Cables DO NOT use commercial telephone cables and extensions. In telephone service, the practice is to flip the wires from e

Seite 30

36 Appendix 4 Serial Ports and Cables Introduction In the following discussion, we use DEVICE to stand for either Digital Dome Works, Dome Wizard,

Seite 31

37 Parallel Cable Options As noted, some CCD cameras require parallel cables. Standard lengths are 10-25 feet. However, you can make or purchase

Seite 32

38 Serial Port Expansion Cards Modern PCs are supplied with two serial ports; one is a 9-pin male and the other a 25-pin female. Typically they ar

Seite 33

39 of IRQ slots. In the scenario, some operating systems other than Windows have the advantage because many can “share” IRQ slots among serial ports

Seite 34

4 Meanwhile, the RFCP has told the controller to consider that it will take some number (e.g., four) microsteps to make one step or count that the RF

Seite 35 - Appendix 3 Serial Cables

40 in the telescope control software). If you now establish connection, you will prove that the control program and the device are both operating co

Seite 36

41 Appendix 5 ASCOM Scripting The RoboFocus Control Program exposes an ActiveX interface and can be invoked with syntax similar to this VBScript e

Seite 37

42 getMaxTravel() As Integer Returns the value of the Maximum Travel field on the Configuration screen, or returns –1 if not connected. getKeepMainO

Seite 38

43 returns the Steps value after the action is complete, or –1 if RoboFocus is offline. If the command was successful, the returned value will equal

Seite 39

44 actOpenComm() As Boolean Opens the Comm Port (if it’s currently closed.) Returns the status of the comm port after the action is completed. actC

Seite 40

45 Appendix 6 Parts List PART DESCRIPTION # RoboFocus Unit Module with processor 1 Power Supply 12V 0.8A positive w 5.5/2.1 plug 1 Instructi

Seite 41 - Appendix 5 ASCOM Scripting

5 2. RoboFocus Installation RoboFocus Software The RoboFocus control program (RFCP) is provided on a CD with other software from Technical Innovat

Seite 42

6 In both versions, under heavy load the sprocket can slip on the inner sleeve, thus acting as a clutch. If you wish to lock them together, put a dr

Seite 44

8 Install the motor base with the timing belt reasonably tight. Once installed, you can change the tension by adjusting the mounting screws on th

Seite 45 - Appendix 6 Parts List

9 about ten minutes. When complete, adjust the bearing tensions so that the focus tube will hold about 5lb without slipping. NGF-S. • Use 3/32 al

Kommentare zu diesen Handbüchern